  Datasheet File OCR Text:
 IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
FAST CMOS 16-BIT BUS TRANSCEIVER/ REGISTER
FEATURES:
* * * * *
IDT54/74FCT162652T/AT/CT
* * * * *
0.5 MICRON CMOS Technology High-speed, low-power CMOS replacement for ABT functions Typical tSK(o) (Output Skew) < 250ps Low input and output leakage 1A (max.) ESD > 2000V per MIL-STD-883, Method 3015; > 200V using machine model (C = 200pF, R = 0) VCC = 5V 10% Balanced Output Drivers: - 24mA (industrial) - 16mA (military) Reduced system switching noise Typical VOLP (Output Ground Bounce) < 0.6V at VCC = 5V, TA = 25C Available in the following packages: - Industrial: SSOP, TSSOP - Military: CERPACK
DESCRIPTION:
The FCT162652T 16-bit registered transceivers are built using advanced dual metal CMOS technology. These high-speed, low-power devices are organized as two independent 8-bit bus transceivers with 3-state D-type registers. For example, the xOEAB and xOEBA signals control the transceiver functions. The xSAB and xSBA control pins are provided to select either real time or stored data transfer. The circuitry used for select control will eliminate the typical decoding glitch that occurs in a multiplexer during the transition between stored and real time data. A low input level selects real-time data and a high level selects stored data. Data on the A or B data bus, or both, can be stored in the internal D-flip-flops by low-to-high transitions at the appropriate clock pins (xCLKAB or xCLKBA), regardless of the select or enable control pins. Flow-through organization of signal pins simplifies layout. All inputs are designed with hysteresis for improved noise margin. The FCT162652T has balanced output drive with current limiting resistors. This offers low ground bounce, minimal undershoot, and controlled output fall times-reducing the need for external series terminating resistors. The FCT162652T is a plug-in replacement for the FCT16652T and ABT16652 for on-board bus interface applications.
FUNCTIONAL BLOCK DIAGRAM
1OEAB 1OEBA 1CLKBA 1SBA 1CLKAB 1SAB B REG
2OEAB 2OEBA 2CLKBA 2SBA 2CLKAB 2SAB B REG
D C
1A1 A REG 1B1 2A1 A REG
D C
2B1
D C
D C
TO SEVEN OTHER CHANNELS
TO SEVEN OTHER CHANNELS
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
1
(c) 2002 Integrated Device Technology, Inc.
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
JUNE 2002
DSC-5451/3
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
PIN CONFIGURATION
1OEAB 1CLKAB 1SAB
ABSOLUTE MAXIMUM RATINGS(1)
56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
Symbol
1OEBA 1CLKBA 1SBA
Description Terminal Voltage with Respect to GND Storage Temperature DC Output Current
Max -0.5 to 7 -0.5 to VCC+0.5 -65 to +150 -60 to +120
Unit V V C mA
VTERM(2) TSTG IOUT
VTERM(3) Terminal Voltage with Respect to GND
GND
1A1 1A2
GND
1B1 1B2
VCC
1A3 1A4 1A5
VCC
1B3 1B4 1B5
NOTES: 1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. All device terminals except FCT162XXX Output and I/O terminals. 3. Output and I/O terminals for FCT162XXX.
GND
1A6 1A7 1A8 2A1 2A2 2A3
GND
1B6 1B7 1B8 2B1 2B2 2B3
CAPACITANCE (TA = +25C, f = 1.0MHz)
Symbol CIN COUT Parameter(1) Input Capacitance Output Capacitance Conditions VIN = 0V VOUT = 0V Typ. 4.5 5.5 Max. 6 8 Unit pF pF
GND
2A4 2A5 2A 6
GND
2B4 2B5 2B6
NOTE: 1. This parameter is measured at characterization but not tested.
VCC
2A7 2A8
VCC
2B7 2B8
PIN DESCRIPTION
Pin Names xAx xBx xCLKAB, xCLKBA xSAB, xSBA xOEAB, xOEBA Description Data Register A Inputs Data Register B Outputs Data Register B Inputs Data Register A Outputs Clock Pulse Inputs Output Data Source Select Inputs Output Enable Inputs
GND
2SAB 2CLKAB
GND
2SBA 2CLKBA 2OEBA
2OEAB
SSOP/ TSSOP/ CERPACK TOP VIEW
2
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
FUNCTION TABLE
Inputs xOEAB L L X H L L L L H H H xOEBA H H H H X L L L H H L xCLKAB H or L H or L X X X H or L H or L xCLKBA H or L H or L X H or L X X H or L xSAB X X X X(2) X X X X L H H xSBA X X X X X X(2) L H X X H xAx Input Input Intput Unspecified(1) Output Output Input Output Data I/O(1) xBx Input Unspecified(1) Output Input Input Input Output Output Operation or Function Isolation Store A and B Data Store A, Hold B Store A in Both Registers Hold A, Store B Store B in both Registers Real Time B Data to A Bus Stored B Data to A Bus Real Time A Data To B Bus Stored A Data to B Bus Stored A Data to B Bus and Stored B Data to A Bus
NOTES: 1. The data output functions may be enabled or disabled by various signals at the xOEAB or xOEBA inputs. Data input functions are always enabled, i.e., data at the bus pins will be stored on every LOW-to-HIGH transition on the clocks inputs. 2. Select control = L: clocks can occur simultaneously. Select control = H: clocks must be staggered to load both registers. 3. H = HIGH Voltage Level L = LOW Voltage Level X = Don't care = LOW-to-HIGH Transition
3
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
BUS A
BUS B
BUS A
BUS B
xOEAB
xOEBA
xCLKAB
xCLKBA
xSAB
xSBA
xOEAB
xOEBA
xCLKAB
xCLKBA
xSAB
xSBA
L
L
X
X
X
L
H
H
X
X
L
X
Real-time Transfer Bus B to A
Real-time Transfer Bus A to B
BUS A
BUS B
BUS A
BUS B
xOEAB xOEBA
xCLKAB
xCLKBA
xSAB
xSBA
xOEAB
xOEBA
xCLKAB
xCLKBA
xSAB
xSBA
X L L
H X H
X
X
X X X
X X X
H
L
H or L
H or L
H
H
Storage From A and/or B 4
Transfer Stored Data to A and/or B
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified: Industrial: TA = -40C to +85C, VCC = 5.0V 10%; Military: TA = -55C to +125C, VCC = 5.0V 10%
Symbol VIH VIL IIH Parameter Input HIGH Level Input LOW Level Input HIGH Current (Input pins) Input HIGH Current (I/O pins) IIL
(4) (4) (4)
Test Conditions(1) Guaranteed Logic HIGH Level Guaranteed Logic LOW Level VCC = Max. VI = VCC
Min. 2 -- -- --
Typ.(2) -- -- -- -- -- -- -- -- -0.7 -140 100 5
Max. -- 0.8 1 1 1 1 1 1 -1.2 -250 -- 500
Unit V V A
Input LOW Current (Input pins) Input LOW Current (I/O pins)
VI = GND
-- --
(4)
IOZH IOZL VIK IOS VH ICCL ICCH ICCZ
High Impedance Output Current (3-State Output pins)(4) Clamp Diode Voltage Short Circuit Current Input Hysteresis Quiescent Power Supply Current
VCC = Max.
VO = 2.7V VO = 0.5V
-- -- -- -80
A
VCC = Min., IIN = -18mA VCC = Max., VO = VCC = Max. VIN = GND or VCC GND(3) --
V mA mV A
-- --
OUTPUT DRIVE CHARACTERISTICS
Symbol IODL IODH VOH VOL Parameter Output LOW Current Output HIGH Current Output HIGH Voltage Output LOW Voltage Test Conditions(1) VCC = 5V, VIN = VIH or VIL, VO = 1.5V(3) VCC = 5V, VIN = VIH or VIL, VO = VCC = Min. VIN = VIH or VIL VCC = Min. VIN = VIH or VIL 1.5V(3) IOH = -16mA MIL IOH = -24mA IND IOL = 16mA MIL IOL = 24mA IND -- 0.3 0.55 V Min. 60 -60 2.4 Typ.(2) 115 -115 3.3 Max. 200 -200 -- Unit mA mA V
NOTES: 1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type. 2. Typical values are at VCC = 5.0V, +25C ambient. 3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second. 4. The test limit of this parameter is 5A at TA = -55C.
5
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
POWER SUPPLY CHARACTERISTICS
Symbol ICC ICCD Parameter Quiescent Power Supply Current TTL Inputs HIGH Dynamic Power Supply Current(4) VCC = Max. VIN = 3.4V(3) VCC = Max. Outputs Open xOEAB = xOEBA = GND One Input Toggling 50% Duty Cycle VCC = Max. Outputs Open fCP = 10MHz (xCLKBA) 50% Duty Cycle xOEAB = xOEBA = GND One Bit Toggling fi = 5MHz 50% Duty Cycle VCC = Max. Outputs Open fCP = 10MHz (xCLKBA) 50% Duty Cycle xOEAB = xOEBA = GND Sixteen Bits Toggling fi = 2.5MHz 50% Duty Cycle VIN = VCC VIN = GND Test Conditions(1) Min. -- -- Typ.(2) 0.5 75 Max. 1.5 120 Unit A A/ MHz
IC
Total Power Supply Current(6)
VIN = VCC VIN = GND
--
0.8
1.7
mA
VIN = 3.4V VIN = GND
--
1.3
3.2
VIN = VCC VIN = GND
--
3.8
6.5(5)
VIN = 3.4V VIN = GND
--
8.3
20(5)
NOTES: 1. For conditions shown as max. or min., use appropriate value specified under Electrical Characteristics for the applicable device type. 2. Typical values are at VCC = 5.0V, +25C ambient. 3. Per TTL driven input (VIN = 3.4V). All other inputs at VCC or GND. 4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations. 5. Values for these conditions are examples of the ICC formula. These limits are guaranteed but not tested. 6. IC = IQUIESCENT + IINPUTS + IDYNAMIC IC = ICC + ICC DHNT + ICCD (fCPNCP/2 + fiNi) ICC = Quiescent Current (ICCL, ICCH and ICCZ) ICC = Power Supply Current for a TTL High Input (VIN = 3.4V) DH = Duty Cycle for TTL Inputs High NT = Number of TTL Inputs at DH ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL) fCP = Clock Frequency for Register Devices (Zero for Non-Register Devices) NCP = Number of Clock Inputs at fCP fi = Input Frequency Ni = Number of Inputs at fi
6
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
54FCT162652T Mil. Symbol tPLH tPHL tPZH tPZL tPHZ tPLZ tPLH tPHL tPLH tPHL tSU tH tW tSK(o) Parameter Propagation Delay Bus to Bus Output Enable Time xOEAB or xOEBA to Bus Output Disable Time xOEAB or xOEBA to Bus Propagation Delay Clock to Bus Propagation Delay xSBA or xSAB to Bus Set-up Time HIGH or LOW Bus to Clock Hold Time HIGH or LOW Bus to Clock Clock Pulse Width HIGH or LOW Output Skew(3) Condition(1) CL = 50pF RL = 500
Min. (2) Max.
54/74FCT162652AT Ind.
Min. (2)
54/74FCT162652CT Ind.
Max.
Mil. 6.3 9.8 6.3 6.3 7.7 -- -- -- 0.5 2 2 2 2 2 2 1.5 5 -- 7.7 10.5 7.7 7 8.4 -- -- -- 0.5 1.5 1.5 1.5 1.5 1.5 2 0 3 --
Mil. Unit ns ns ns ns ns ns ns ns ns 3.9 4.8 4.4 4.1 4.2 -- -- -- 0.5 1.5 1.5 1.5 1.5 1.5 2 1.5 5 -- 6 8.9 7.7 6.3 7 -- -- -- 0.5
Max. Min. (2)
Min.(2) Max. Min. (2) Max.
2 2 2 2 2 4.5 2 6 --
11 15 11 10 12 -- -- -- 0.5
2 2 2 2 2 2 1.5 5 --
NOTES: 1. See test circuit and waveforms. 2. Minimum limits are guaranteed but not tested on Propagation Delays. 3. Skew between any two outputs of the same package switching in the same direction. This parameter is guaranteed by design.
7
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
TEST CIRCUITS AND WAVEFORMS
V CC 500 VIN Pulse Generator RT D.U.T. 50pF CL 500 VOUT
7.0V
SWITCH POSITION
Test Open Drain Disable Low Enable Low All Other Tests Switch Closed Open
DEFINITIONS: CL = Load capacitance: includes jig and probe capacitance. RT = Termination resistance: should be equal to ZOUT of the Pulse Generator.
Test Circuits for All Outputs
3V 1.5V 0V 3V 1.5V 0V 3V 1.5V 0V 3V 1.5V 0V
DATA INPUT TIMING INPUT ASYNCHRONOUS CONTROL PRESET CLEAR ETC. SYNCHRONOUS CONTROL PRESET CLEAR CLOCK ENABLE ETC.
tSU
tH
LOW-HIGH-LOW PULSE tW HIGH-LOW-HIGH PULSE
1.5V
tREM
1.5V
tSU
tH
Pulse Width
Set-up, Hold, and Release Times
ENABLE SAME PHASE INPUT TRANSITION tPLH OUTPUT tPLH OPPOSITE PHASE INPUT TRANSITION tPHL tPHL 3V 1.5V 0V VOH 1.5V VOL 3V 1.5V 0V CONTROL INPUT tPZL OUTPUT NORMALLY LOW OUTPUT NORMALLY HIGH SWITCH CLOSED tPZH SWITCH OPEN 1.5V 0V 3.5V 1.5V tPHZ
DISABLE 3V 1.5V tPLZ 0V 3.5V 0.3V 0.3V VOL VOH 0V
Propagation Delay
Enable and Disable Times
NOTES: 1. Diagram shown for input Control Enable-LOW and input Control Disable-HIGH. 2. Pulse Generator for All Pulses: Rate 1.0MHz; tF 2.5ns; tR 2.5ns.
8
IDT54/74FCT162652T/AT/CT FAST CMOS 16-BIT BUS TRANSCEIVER/REGISTER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
ORDERING INFORMATION
IDT FCT XX Temp. Range XXX Family XXXX Device Type XX Package X Process Blank B Industrial MIL-STD-883, Class B Industrial Options Shrink Small Outline Package Thin Shrink Small Outline Package
PV PA
E
Military Options CERPACK
652T 652AT 652CT
16-Bit Bus Transceiver/Register
162 54 74
Double-Density, 5 Volt, Balanced Drive - 55C to +125C - 40C to +85C
DATA SHEET DOCUMENT HISTORY
3/28/2002 6/27/2002 Removed standard speed grade Updated according to PDNs Logic-00-07 and Logic-01-04
CORPORATE HEADQUARTERS 2975 Stender Way Santa Clara, CA 95054
for SALES: 800-345-7015 or 408-727-6116 fax: 408-492-8674 www.idt.com
for Tech Support: logichelp@idt.com (408) 654-6459
9


▲Up To Search▲   

 
Price & Availability of IDT74FCT162652CT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X